Large Spreading Caliper, Metrisis Anthropometry Portable Solo Abadi Passe Calibration Test

Surakarta, PT Solo Abadi Indonesia — Products from PT Solo Abadi Indonesia namely Large Spreading Caliper, metritis anthropometry portable pass the calibration test. This calibration was carried out by the medical calibration team of PT Indraloka in Sukoharjo. Large Spreading Capiler is an instrument of human body measurement to measure body parts that are not flat. This calibration is done to find out that the measuring instrument produced by PT Solo Abadi Indonesia is by measurement standards to increase consumer confidence in using measuring instruments accurately.

 the form of large spreading caliper measuring instrument from pt solo abadi indonesia that has passed the calibration test
Large Spreading Caliper Measuring Instrument from PT Solo Abadi Indonesia

Calibration is a verification process to see the accuracy of a measuring instrument that has been designed by comparing national standard with verified reference materials. The purpose of this calibration is to achieve measurement smoothness by measurement standardization.

The calibration test process takes approximately one week. Starting from December 22, 2021, PT Solo Abadi submitted a calibration of the Large Spreading Caliper tool to PT Indraloka. The test passed the calibration of the tool on December 28, 2021 with the issuance of the certificate passing the calibration test. Calibration tests of this tool were conducted at the mass laboratory, PT Indraloka on December 27, 2021. This calibration test was conducted by calibration technician Alfri Seno Wibowo, AMTE.

The final results of calibration tests on the Large Spreading Capiler tool state that the measuring instrument is traceable to the International System of Units. With the result of uncertainty the measurement has a confidence level of 95% with a coverage factor (k) of 2.0 mm. Large Spreading Capiler was tested with the MK/LK-INDLK/TB-01 method. Calibration results on this measuring instrument are declared safe for use in health services.

Calibration tests on Large Spreading Caliper tools use equipment that is by calibration standards, namely smart tape measuring and thermohygrometer. In addition, this calibration test also mentions the body and the condition, controls, and indicators, as well as cables and accessories tools in the good physical condition and also in good function.

About PT Solo Abadi Indonesia

PT Solo Abadi Indonesia is a company located in Surakarta, Central Java. Engaged in manufacturing and is the largest manufacturer of light embosslight slitting, light feederportable anthropometricportable stadiometerinfantometer boardskinfold caliperanthropometric chair, and stunting kit in Indonesia which was established in 2005. Solo Abadi products can be applied in various fields of science such as health, anthropology, forensics, industrial engineering, product design, academies, to the military.